📈 Solar & electronics ERP: Yield & testing

Know the real yield, station by station, unit by unit

Every test result linked to the unit's serial: first-pass and rolled throughput yield, flash tests that set each module's power class, control charts that warn before parts drift out, and burn-in that catches early failures.

Inverter control board, 1,000 unitsRTY 0%

Flash test

Every module binned on what it really makes

A simplified I-V curve for a 550 Wp class module. Change irradiance and cell temperature to see power and the bin. Illustrative model.

0
0

Control chart

Catch the drift before the defect

Output voltage at functional test, one point per batch of five. Press Play to stream it. Points breaking a rule turn red. Demo data.

Target 10.00 V, control limits 9.91 to 10.09 V.

Burn-in

Fail in the factory, not at the customer

The bathtub curve: failure rate over a product's life. Longer burn-in screens more early failures but costs chamber time. Illustrative.

0

How it works

From test logs to live yield

Six steps to go live.

  1. Step 1Map stationsTests, limits and fail codes.
  2. Step 2Connect testersFlash testers, ICT, FCT.
  3. Step 3Set limitsSpec and control limits.
  4. Step 4Load productsTest plans per model.
  5. Step 5Train teamsRepair and analysis.
  6. Step 6Go liveStation by station.
What it changes

Results quality and customers notice

What changes once every test result is in one place.

Higher yield

Losses seen by station, fixed at the source.

Right power labels

Every module binned on its measured power.

Earlier warnings

Drifts caught before they become failures.

Proof for customers

Test records by serial, on request.

Who it's for

Built for solar and electronics makers

From one test bay to a multi-plant group.

  • Solar module manufacturers
  • Inverter and power electronics makers
  • EMS and PCB assemblers
  • Battery and BMS makers
  • LED and lighting manufacturers
  • Automotive electronics suppliers
Solar & electronics ERP

Other modules in the suite

One integrated system.

FAQ

Yield and testing questions

Answers for quality heads, test engineers and plant managers.

What is yield and test management software?

Software that collects every test result, from AOI and in-circuit tests to flash tests and burn-in, works out yields, flags drifts and links each result to the unit's serial number.

What is first-pass yield?

The share of units that pass a station the first time, without rework or retest.

What is rolled throughput yield?

First-pass yields of all stations multiplied together. Four stations at 97% each give about 88.5%, the real chance a unit gets through untouched.

What is a flash test?

A solar module is lit by a short, calibrated flash of simulated sunlight while its I-V curve is measured. Its maximum power sets the power class on the label.

What is power binning?

Sorting modules into classes such as 545, 550 or 555 Wp by measured power, usually with positive-only tolerance so customers never get less than the label.

What does SPC do?

Statistical process control plots a measurement over time against control limits and flags patterns, such as a run of points on one side, before parts go out of spec.

Why do burn-in?

Many electronic failures happen early in life. Running units under stress for hours weeds them out in the factory instead of at the customer.

Can it import data from our testers?

Yes. Results are imported from test equipment by file or interface, mapped to stations and serials.

How long does implementation take?

As an estimate, 4 to 8 weeks, depending on the number of testers and how they export data.

Get In Touch

Ready to see yield at every station, live?

Tell us your products, test stations and current tools. We reply within 4 business hours.

⏰
Response TimeWithin 4 business hours (your timezone)
Trusted by clients worldwideIndia · Australia · Fiji · Globally
15+Years of expertise
500+Projects delivered
3Countries served
✓ Free consultation✓ Reply in 4 business hours✓ NDA on request